CFV-MZJ560B1 Veterinary Anesthesia Machine

CFV-MZJ560B1 Veterinary Anesthesia Machine

  • The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose onekind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
  • The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose onekind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
  • Reliable pneumatic transmission system.
  • Economic and proper configuration of technologies, optional as required by the Customer.
  • Modularized design and upgrading. Upgrading is available as required by the Customer.

 

Part of Anesthesia

■Main body                  High-strength engineering plastic rack, light,

beautiful and corrosion resistant

■Scope of application           adult, child

■Gas source                  O2, N2O: 0.27~0.55MPa

■Flow meter                  O2: 0.1~1.0L/min    1.1~10L/min

■Flow rate of rapid oxygen supply  25~75L/min

■Low oxygen pressure alarm     There will be sound alarm when the oxygen

pressure < 0.2MPa

■Vaporizer                   it has the function of automatic compensation based on pressure,temperature,and flow rate. The regulation range of evaporator concentration is 0~5 vol%.

Among Halothane,Enflurane,Isoflurane and Sevoflurane,one can be chosen for application as required by the customer.

■Respiratory circuit             working mode: all-close, semi-close, semi-open

                             releasing pressure: 0.5~7 kPa

■Respiratory bellows            bellows for adults, bellows for children 

tidal volume range:0~1500 ml

 

Part of Ventilator

■Display mode                 High-definition 4.8” LCD screen display

■Ventilation  mode             IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate)

■Ventilation parameters          Tidal volume         50~1500ml

Rate                4~80 bpm

I:E                2:1~1:4

Pressure range        1.0~6.0 kPa

■Parameters for ventilation monitoring   tidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure – time waveform

■Security Alarm System

Airway pressure alarm          upper limit setting range  1.0~6.0 kPa

low limit setting range    0.4~2.0 kPa

TV alarm                            upper limit setting range   0.5~2.0L

low limit setting range     0.02~1.0L

Sustained high-pressure alarm      it will give alarm when stress have consistently

been higher than 2.5 kPa

Suffocation alarm              it will give sound and light alarm if there is

no tidal volume input in 15s

Power alarm

■Power                           AC 220V±10%     50Hz±1Hz